The following NHS Safety Notices has been received –

  1. An incident was reported where a nebuliser was directly connected to a cuffed tracheostomy tube resulting in patient barotrauma. When incorporating a nebuliser into a breathing system with an endotracheal or tracheostomy tube, check the performance of the system is not adversely affected with regard to free passage of expired air.
  2. Arjo 4 Point Slings for patient lifting. Arjo report a potential problem with blue four-point slings with grey attachment clips.
  3. Zoll M Series Advisory Defibrillator & AED Defibrillator. Spurious noises generated during charging may interfere with correct detection of ventricular fibrillation, as a result ECG might be interpreted as non-shockable even in the presence of underlying shockable ventricular fibrillation.

If you need further information on any of the above contact Safety Services on 26198

------------------------------------------------------------------

Do not use fused 4-plug extension leads plugged into other fused 4-plug extension leads to overcome a lack of electrical sockets for PC’s and associated equipment. Other equipment requiring relatively high amperages, e.g. kettles and heaters, could also be connected which could exceed the capacity of the single 13 amp socket and result in a fire. If you need more electrical wall sockets in rooms, contact Estates Services urgently to arrange this. There may be a cost involved providing new sockets, but the costs of not doing so could be a lot higher.

------------------------------------------------------------------

Amended Control of Asbestos at Work Regulations are likely to be issued this year with a new Code of Practice, requiring employers to survey all non-domestic premises occupied by them, and in which persons work, to assess whether asbestos is, or is liable to be, present. Estates Services are to survey all University buildings this year, in anticipation of the legal requirement, to establish the extent of the problem. Surveys will identify surface materials containing asbestos, but not asbestos hidden behind surfaces. Contact Estates Services if you need work done in your department that requires drilling, or removal, of wall or ceiling panels.

------------------------------------------------------------------

Stanley Handling Ltd have sent information through on "Powered Stairclimbers", battery powered sack-trucks/trolleys able to "climb" stairs. They’re not cheap, but if moving heavy items or equipment up and down stairs is a common practice in your work area, then this could be a real benefit. Contact Safety Services on 26198 for more information.

------------------------------------------------------------------

HSE have just issued Catering Information Sheet No. 21, Health and safety of children and young people in catering. This can be obtained free from HSE Books on 01787 881165.

------------------------------------------------------------------

Safe Use of Cryogenic Liquids - information can be found on the Safety Services web pages in the "Guidance" section. If you use cryogens make sure you are fully acquainted with the risks and safe working procedures. For more advice speak to your Departmental Safety Officer.

------------------------------------------------------------------

You may have received information about the Sheffield City Council Evacuation Plan. The University is co-operating with the City Council and has nominated Brian Mole, Len Wilson and Dewi Thomas as Co-ordinators for Zone 1.

------------------------------------------------------------------

Occupational Exposure Limits (Safetyline 14). The correct web address for the abbreviated list is http://www.hse.gov.uk/press/C01043.htm. Full list is available in HSE document EH40 /2001

------------------------------------------------------------------

Current Accident Books are luminous green. Contact Safety Services if you need replacements.

------------------------------------------------------------------

Departmental emergency contact telephone numbers for Emergency Control Centre. Names provided by one department had left the University some months previously. Please ensure that contact numbers held by ECC for your department are current, by ringing Dionne Edwards on 26198.

 